Calibrating the pH Sensor in a Pool Salt Chlorination System: Why It Matters and How to Do It
Anyone with experience can confirm it: switching from disinfecting pool water with methods like liquid chlorine or chlorine tablets to using a salt chlorinator changes everything, since it's the safest and most effective way to eliminate bacteria and keep the water clean. A salt chlorinator is safe, effective, and economical. With Magen Eco-Energy's advanced new generation salt systems, such as the Resilience D Plus, you can enjoy complete peace of mind, since the device monitors and balances the water on its own. That said, it's important to recalibrate the system's existing pH sensor periodically, once a year, or whenever you suspect the sensor may be inaccurate, to make sure it's measuring water quality correctly.
In the following section, we'll explain why calibration is necessary and how to complete the process in a few simple steps.
The Resilience D Plus monitoring system includes two sensors that continuously measure and monitor water quality. The readings from these sensors determine the salt chlorinator’s chlorine production rate in real time. When the system is installed, the sensors are calibrated by the installer. Calibration is performed to make sure the sensors provide reliable information about the environment they’re immersed in. This is done by soaking the sensor in two different pH solutions: pH 7.0 and pH 4.0.
How Is This Done in Practice?
Before starting the calibration process, open the calibration solution pouches and have a cup of clean tap water ready.
Step one: soaking in pH 7.0 solution:
Turn off the circulation pump and the control panel. On the control panel, press the M button to enter calibration mode, then press it again to start the pH calibration process. The display will show 7.0USE pH.
Remove the pH sensor from its position in the piping and immerse it in the pH 7.0 solution (yellow pouch). Wait about twenty seconds for the readings to stabilize, then press the M button to confirm.
Step two: soaking in pH 4.0 solution:
The display will now show 4.0USE pH. Remove the sensor from the pH 7.0 solution. Dip the sensor in the cup of water and shake it gently to remove any residual liquid. Place the sensor in the pH 4.0 solution (red pouch). Wait for the readings to stabilize, then press the M button. The screen will now display DONE, meaning the calibration process is complete. Reinstall the sensor in the piping. Turn the circulation pump and control panel back on to return the system to operation.